ID 14371
Spindle speed not defined. | |||
Description | A valid spindle speed must be programmed and the spindle must be activated by M3/M4 before the cycle is called up. | ||
Response | Class | - | Error: Transition to error state. Complete reset of the NC channel necessary. |
Solution | Class | - | Specify a valid spindle speed and activate the spindle before the cycle is called. |
Error type | 1, Error message from the NC program | ||
|