ID 14368
The corrected safety level exceeds the retraction level. | |||
Description | In the cycle, the safety distance specified in the input parameters is corrected slightly upwards to allow the correct thread pitch. The correction means that the specified retraction plane cannot be maintained. | ||
Response | Class | - | Error: Transition to error state. Complete reset of the NC channel necessary. |
Solution | Class | - | Increase the retraction level or reduce the safety distance. |
Error type | 1, error message from the NC program | ||
|