Lower limit for measuring system (P-CHAN-00807)

P-CHAN-00807

Lower limit for measuring system

Description

The following value defines the lower limit of the sensor. An error message is output if this limit is exceeded when distance control is active.

Parameter

dist_ctrl[i].min_pos (where i=0)

Data type

SGN32

Data range

0 <= min_pos < MAX(SGN32)

Dimension

[0.1 10^-3 mm or ø]

Default value

-50000

Remarks

Available as of Build V3.1.3080.12 or V3.1.3107.44