Diagnosis upload mode (P-STUP-00117)

P-STUP-00117

Diagnosis upload mode

Description

This parameter defines the mode for a diagnosis upload.

For an overview of the possible settings, see the Mode Table

Parameter

configuration.diagnosis_upload.mode

Data type

STRING

Dimension

---

Default value

STANDARD

Remarks

Parameter available as of CNC Build V2.11.2059, V2.11.2830, V3.1.3079.43 or V3.1.3107.33.

Diagnosis upload mode

Meaning

STANDARD

Default upload with no further functions

REGRESSION

Formatting for regression test

PROTOCOL_INFO

Additional information about the upload procedure

MSG_FLUSH_OFF

Deactivate automatic flush for messages to ISG_DIAG_BED at the start of the diagnosis upload.