ID 51073

There are too many NC control commands programmed between #ESCAPE PATH BACKWARD STOP and #ESCAPE PATH DEF END.

Description

Only a limited number of control commands is permitted between the NC commands #ESCAPE PATH BACKWARD STOP and #ESCAPE PATH DEF END. An unlimited number of movement blocks can be programmed between the commands.

#ESCAPE PATH Command structure:

  1. #ESCAPE PATH DEF BEGIN
  2. #ESCAPE PATH BACKWARD STOP
  3. #ESCAPE PATH POST SEQUENCE
  4. #ESCAPE PATH DEF END

Response

Class

2

NC program execution aborted and transition to error state

Solution

Class

3

Check and modify the NC program; reduce the control commands after
#ESCAPE PATH BACKWARD STOP.

Parameter

%1:

Current value [-]

Block number of control command that exceeds the permitted number.

Error type

1, Error message from NC program.