Number of bits for command value (P-AXIS-00816)

P-AXIS-00816

Number of bits for command value

Description

This parameter limits the command value output by the position controller to the value range that can be used by the drive or terminal.

Parameter

kenngr.bit_range_comand_value

Data type

UNS16

Data range

8…32

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

32

Drive types

Conventional, SERCOS, Terminal, Lightbus, Profidrive, CANopen, DSE

Remarks

Available as of CNC Build V3.1.3080.06