KIN_TYP_98- Transformation to monitor the minimum distance

Release Note

release_note

This function is available as of V3.1.3080.12 or V3.1.3107.44

This transformation can monitor and maintain a defined minimum distance to the workpiece surface at the tool inclination.

Monitoring the minimum distance
Monitoring the minimum distance

The laser length L1 must be programmed as the tool length, e.g. programmed via V.G.WZ_AKT.L.

Tool length L2 is the tool length that is extended by the kinematic due to the avoidance motion.

Offset data of kinematics

HD offset

param[i]

Description

Unit

HD1

0

Tool clamping point offset up to tool head reference point

1.0 E-4 mm

HD2

1

Inclination angle starting at which the distance of the tool head to the surface is kept constant.

1.0 E-4°

HD3

2

Maximum inclination angle starting at which the distance of the tool head to the surface is kept constant.

1.0 E-4°

HD4

3

Maximum inclination angle. When exceeded, an error message is output with process abort.

1.0 E-4°