Activate acknowledgement for signals (P-STUP-00118)

P-STUP-00118

Activate acknowledgement for signals

Description

This parameter activates a mode that waits until storage of the signal is acknowledged with default signals sent at decoder level.

This does not affect broadcast signals and synchronised signals at interpolator level (#SIGNAL SYN[…]) .

The maximum number of stored events can be defined in P-STUP-00119.

Error ID 250001 can no longer occur at decoder level if P-STUP-00118 is set.

Parameter

signal_wait.use_signal_acknowledge

Data type

BOOLEAN

Data range

0: Function deactivated

1: Function activated

Dimension

---

Default value

0

Remarks