ID 310011

Master axis not programmed for measurement run.

Description

A master axis must be specified in order to use the measurement function of distance control.

Response

Class

7

Controlled halt of the axis, the control loop is closed.

Solution

Class

6

Program the master axis in the keyword “AX1“ or “AX2“.

Parameter

%1:

Logical axis number [-] or Logical channel number [-]

Logical axis number Axis parameters of the axis affected for axis-specific distance control,
logical channel number Logical number of a NC channel (P-CHAN-00400) for 3D distance control.

%2:

Block number [-]

Block number in the NC program

%3:

Logical axis number [-]

Logical axis number Axis parameters of axis AX1

%4:

Logical axis number [-]

Logical axis number Axis parameters of axis AX2

Error type

-