ID 310023

During deselection of distance control, it was activated again.

Description

Distance control was deactivated and then re-activated immediately afterwards. After deactivation, wait until the existing compensation offset has finished before re-activating distance control.
Alternatively, distance control can be disabled with the addition NO_MOVE without clearing the existing compensation offset.

See:

Response

Class

7

Controlled halt of the axis, the control loop is closed.

Solution

Class

6

Check and modify the process.
Possibly disable distance control using OFF NO_MOVE to avoid clearing the existing compensation offset.

Parameter

%1:

Logical axis number [-] or Logical channel number [-]

Logical axis number Axis parameters of the axis affected for axis-specific distance control,
logical channel number Logical number of a NC channel (P-CHAN-00400) for 3D distance control.

%2:

Block number [-]

Block number in the NC program

Error type

-