Start position of master axis 2 (P-COMP-00013)

P-COMP-00013

Start position of master axis 2

Description

This parameter determines the start position of master axis 2 in the compensation table.

Parameter

kw.crosscomp2.start_position_master2

Data type

SGN32

Data range

MIN(SGN32) ≤ start_position_master2 < MAX(SGN32)

Axis types

T, R, S

Dimension

T: 0.1 µm or increments

R,S: 0.0001° or increments

Default value

0

Remarks