Example of a compensation value list

The diagram below shows a compensation value table with the properties:

Programmed
position
ith setpoint

Measured value pos
ith actual value
(pos direction)

Measured value neg
ith actual value
(neg direction)

pos calculated
compensation value

neg calculated
compensation value

19866.7 μm

19856.5 μm

19874.7 μm

-102 x 0.1 μm

80 x 0.1 μm

Programing Example

prg_example

Example of a compensation value list

kopf.log_achs_nr                     2

kopf.log_achs_name                   Y-ACHSE

kw.ssfk.interval                     0

kw.ssfk.kw_startpos                 -200000

kw.ssfk.kw_nr_max                    140

kw.ssfk.unit                         1

kw.ssfk.bilateral                    1

kw.ssfk.table[0].setpoint           -200000

kw.ssfk.table[1].setpoint           -199306

kw.ssfk.table[2].setpoint           -198667

kw.ssfk.table[3].setpoint           -198001

...

kw.ssfk.table[138].setpoint          334488

kw.ssfk.table[139].setpoint          335591

kw.ssfk.table[0].pos                 0

kw.ssfk.table[1].pos                 24

kw.ssfk.table[2].pos                -102

...

kw.ssfk.table[139].pos               -55

kw.ssfk.table[0].neg                 0

kw.ssfk.table[1].neg                 67

kw.ssfk.table[2].neg                 80

...

kw.ssfk.table[139].neg               114