Logical axis number of second adaptation axis (P-COMP-00081)

P-COMP-00081

Logical axis number of the second adaptation axis

Description

This parameter defines the logical axis number of the second adaptation axis. The position of the adaptation axis influences compensation in Mode 3 (P-COMP-00082).

Parameter

kw.crosstalk.master_pos2_ax_nr

Data type

UNS16

Data range

0 < P-COMP-00081 < MAX(UNS16)

Axis types

T

Dimension

T: ----

R, S: -

Default value

0

Remarks