Homing without cam (P-AXIS-00156)
P-AXIS-00156 | Homing without cam | |
Description | A changeover of homing strategy can be carried out so that homing is done without cam (e.g. only with zero pulse), i.e. without reverting. In this case the parameter P-AXIS-00156 should be set to TRUE. | |
Parameter | kenngr.ref_ohne_nocken | |
Data type | BOOLEAN | |
Data range | 0/1 | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
drive types. | Conventional, Terminal, Lightbus, Profidrive | |
Remarks | To be assigned for analogue spindles only. If P-AXIS-00156 is assigned with 1 (TRUE), then it is imperative that P-AXIS-00157 is assigned with 1 (TRUE). |