Slow velocity for exact detection of reference position (P-AXIS-00218)

P-AXIS-00218

Slow velocity for exact detection of reference position

Description

Not only the traverse downwards of cam but also the traverse on cam with homing takes place at the velocity P-AXIS-00218.

Parameter

getriebe[i].vb_reflow

Data type

UNS32

Data range

1 ≤ vb_reflow ≤ P-AXIS-00219

Axis types

T, R, S

Dimension

T: µm/s

R,S: 0.001°/s

Default value

16666

drive types.

Simulation, Conventional, Terminal, Lightbus, Profidrive

Remarks