Homing only with cam (without zero pulse) (P-AXIS-00084)

P-AXIS-00084

Homing only with cam (without zero pulse)

Description

The homing position is detected by travel on the cam.

Parameter

kenngr.homing_without_zero_pulse

Data type

BOOLEAN

Data range

0: Homing with zero pulse of rotary transducer (default value).

1: Homing without zero pulse of rotary transducer (low accuracy).

Axis types

T, R

Dimension

T: ----

R:----

Default value

0

drive types.

----

Remarks

For further hardware-specific parameters relating to homing with cam, see P-AXIS-00036 - P-AXIS-00039.