Negative software limit switch (P-AXIS-00177)

P-AXIS-00177

Negative software limit switch

Description

The parameter defines the possible traverse range in the negative direction (negative software limit switch position). The programmed command positions are always checked on 'kenngr.swe_neg', the actual positions on 'kenngr.swe_neg - kenngr.swe_toleranz'.

Parameter

kenngr.swe_neg

Data type

SGN32

Data range

MIN(SGN32) < swe_neg < P-AXIS-00178

Axis types

T, R

Dimension

T: 0.1µm

R: 0.0001 °

Default value

-100000000

drive types.

----

Remarks

The value of the parameter is adopted on reset, mode change and axis replacement from the axis record.