SERCOS-status bit for measurement (P-AXIS-00106)
P-AXIS-00106 | SERCOS-status bit for measurement | |
Description | This bit coded parameter (f. e. 0x0040) defines the status bit for SERCOS measurement which monitors the status of measuring probe activated/not activated. | |
Parameter | lr_hw[i].mask_mess_1 | |
Data type | UNS16 | |
Data range | 0x0040: Status bit 1 0x0080: Status bit 2 | |
Axis types | T, R | |
Dimension | T: ---- | R: ---- |
Default value | 0x0080 | |
Drive types | SERCOS | |
Remarks |
|