Name process data 'enable probe 1' (P-AXIS-00675)
P-AXIS-00675 | Name process data 'enable probe 1' | |
Description | This parameter defines the bit that is transferred to a specific cyclical process data element to enable probe 1 to drive SERCOS drives. When one of the real-time control bits of the SERCOS control word is used, this parameter has to be set to 'S-0-0134' or 'S_0_0134'. In all other cases enter the name of the process data element in the process data configuration. If this parameter is used, enter the number of the bit used in P-AXIS-00676 . | |
Parameter | antr.sercos.probe_1_realtime_bits.start_probing.element_name | |
Data type | STRING | |
Data range | - | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | * | |
Drive types | SERCOS | |
Remarks | If the configured element name is not found in the process data, an error message P-ERR-110612is output. The axis parameters P-AXIS-00118 (messachse) and P-AXIS-00098 (kasto_axis) are then reset to prevent the execution of a measurement travel or edge banding with incompletely configured probes. * Note: The default value of variables is a blank string. |