Measurement with movement to a fixed stop (P-AXIS-00330)
P-AXIS-00330 | Measurement with movement to a fixed stop | |
Description | This parameter enables the measurement signal source 'Fixed stop'. | |
Parameter | kenngr.meas_signal_fixed_stop | |
Data type | BOOLEAN | |
Data range | 0/1 | |
Axis types | T, R | |
Dimension | T: ---- | R: ---- |
Default value | 0 | |
Drive types | Conventional, SERCOS, Terminal, Lightbus, Profidrive, CANopen | |
Remarks | The user must ensure that, during movement to a fixed stop in the drives affected, a torque limitation is active and the velocity is low enough. All other measurement signal sources (e.g. P-AXIS-00116) must be deselected. For measurement with movement to a fixed stop, the parameters P-AXIS-00331 or P-AXIS-00332 are also required. |