Behaviour on setting the homing position (P-AXIS-00445)
P-AXIS-00445 | Behaviour on setting the homing position | |
Description | This parameter defines the behaviour on setting the homing position for a gantry slave axis (see [HLI//Control commands of an axis]. | |
Parameter | kenngr.gantry_independent_set_refpos | |
Data type | BOOLEAN | |
Data range | 0: If the home position is set for the master axis, the home position is also set in the same cycle for all gantry slave axes belonging to this master axis. 1: If the parameter is set to 1 for a gantry slave axis, the homing position can be set independently of its master axis. Setting the homing position on the gantry master axis has no influence for this slave axis. | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
Drive types | ---- | |
Remarks |
|