Average value filter for current master velocity (P-AXIS-00300)
P-AXIS-00300 | Average value filter for current master velocity for camming / gearing | |
Description | This parameter activates the arithmetic average value filter for the mast actual velocity. This parameter is used for gearing at the current master velocity. | |
Parameter | cam_gear.mv_type | |
Data type | UNS16 | |
Data range | 0/1 | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
Drive types | ---- | |
Remarks |
|