Ignore feedhold at position correction after drive enable (P-AXIS-00356)

P-AXIS-00356

Ignore feedhold at position correction after drive enable

Description

This parameter determines if a position correction after drive enable (see also P-AXIS-00327) can be interrupted with axis- or channel-specific feedhold.

If this parameter has the value 1, a position correction can not be stopped with feedhold.

Parameter

kenngr.pos_corr_ignore_feedhold

Data type

BOOLEAN

Data range

0/1

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

SERCOS, Lightbus