Feedhold mode (P-AXIS-00540)

P-AXIS-00540

Feedhold mode to select the active feedhold interface

Description

This parameter enables the selection of the effective feedhold interface(s) of independent axes.

Parameter

kenngr.indp_feedhold_mode

Data type

UNS16

Data range

0: Feedhold from channel and axis interface (default).

1: Feedhold from axis interface

Axis types

T, R

Dimension

T: ----

R: ----

Default value

0

Drive types

----

Remarks

The term independent axes covers all functions comprising single axis interpolators (INDP, SAI) except for manual mode. This does not affect the function of internal feedhold interfaces (e.g. CNC reset).

For manual mode, the effect of feedhold control signals can be defined by the parameter P-AXIS-00529 .