Suppress stop of spindle axis during channel reset (P-AXIS-00455)

P-AXIS-00455

Suppress stop of spindle axis during channel reset

Description

By default a spindle axis which is commanded by M3, M4 or M19 is stopped during channel reset. The stop of the spindle axis can be suppressed by setting this parameter to 1 (TRUE).

Parameter

kenngr.no_stop_by_channel_reset

Data type

BOOLEAN

Data range

0/1

Axis types

S

Dimension

 

S: ----

Default value

0

Drive types

----

Remarks