Acceleration of step 2 (P-AXIS-00012)

P-AXIS-00012

Acceleration of step 2 (linear slope)

Description

The parameter only becomes active during the deceleration phases. It defines the acceleration in step 2.

Parameter

getriebe[i].lslope_profil.a_stufe_2

Data type

UNS32

Data range

1 ≤ a_stufe_2 ≤ P-AXIS-00008

Axis types

T, R, S

Dimension

T: mm/s²

R,S: °/s²

Default value

1000

Drive types

----

Remarks

The acceleration ramps can be changed in the NC program. The appropriate NC commands are described in detail in [PROG//G130, G131] in greater detail.