Upper limit for measuring system (P-AXIS-00419)
P-AXIS-00419 | Upper limit for measuring system | |
Description | The following parameter defines the upper limit of the sensor. An error message is generated if it is exceeded while distance control is active. | |
Parameter | kenngr.distc.max_pos | |
Data type | SGN32 | |
Data range | 0 ≤ max_pos < MAX(SGN32) | |
Axis types | T, R | |
Dimension | T: 0.1µm | R: 0.0001 ° |
Default value | 50000 | |
drive types. | SERCOS, Profidrive, CANopen | |
Remarks |
|