Order of the filter (P-AXIS-00507)

P-AXIS-00507

Order of the filter

Description

The filter's order describes its behaviour with regard to the drop in the frequency response.

The following applies: Frequency drop = - P-AXIS-00507 * 20 dB/decade

Parameter

kenngr.distc.low_pass_filter_order

Data type

UNS32

Data range

0 … 6

Axis types

T, R

Dimension

T: ----

R: ----

Default value

4

drive types.

SERCOS, Profidrive, CANopen

Remarks