Order of the filter (P-AXIS-00507)
P-AXIS-00507 | Order of the filter | |
Description | The filter's order describes its behaviour with regard to the drop in the frequency response. The following applies: Frequency drop = - P-AXIS-00507 * 20 dB/decade | |
Parameter | kenngr.distc.low_pass_filter_order | |
Data type | UNS32 | |
Data range | 0 … 6 | |
Axis types | T, R | |
Dimension | T: ---- | R: ---- |
Default value | 4 | |
drive types. | SERCOS, Profidrive, CANopen | |
Remarks |
|