Permanent activation of feedforward control (P-AXIS-00255)

P-AXIS-00255

Permanent activation of feedforward control

Description

This parameter activates feedforward control permanently for one axis. Feedforward control is active all the time, even if G137 is active in the channel (or NC program).

Parameter

vorsteuer.default_active

Data type

BOOLEAN

Data range

0/1

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

----

Remarks

This function is available for all types of axes and types of drives.