Time constant low-pass filter position lag (P-AXIS-00190)
P-AXIS-00190 | Time constant low-pass filter position lag | |
Description | This parameter activates a low-pass filter for the calculated position lag. At the moment, this filter is only effective for Profidrive drives in DSC mode. For these drives the position lag calculated is filtered with a first-order low-pass filter of the given time constant before it is transmitted to the drive. | |
Parameter | vorsteuer.timeconst_cmd_filter | |
Data type | UNS32 | |
Data range | 0 … MAX_UNS32 | |
Axis types | T, R | |
Dimension | T: µs | R: µs |
Default value | 4000 | |
Drive types | Profidrive | |
Remarks | Only effective for PROFIDRIVE drives in DSC mode. |