Time base for normalisation of velocity (P-AXIS-00207)

P-AXIS-00207

Time base for normalisation of velocity

Description

The time base for adapting the velocity interface to the unit used in the drive can be specified as value per minute, second or sampling interval. If normalisation per sampling interval is selected, the output value changes proportionally depending on the CNC cycle time at constant velocity. This may be essential depending on the drive.

Parameter

antr.v_time_base

Data type

UNS16

Data range

0: per minute

1: per second

2: per sampling interval

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

SERCOS

Remarks