Numerator of natural frequency of axis simulation (P-AXIS-00062)

P-AXIS-00062

Axis simulation natural frequency (numerator)

Description

The parameter defines the axis simulation natural frequency (numerator).

Natural frequency = P-AXIS-00062 / P-AXIS-00061

Parameter

antr.simu.eigenfrequenz_z

Data type

UNS32

Data range

MAX(UNS32) ≥ eigenfrequenz_z ≥ 1

Axis types

T, R, S

Dimension

T: 1

R,S: 1

Default value

100

Drive types

Simulation

Remarks

The value of ω0 is specified directly.