Time slot calculation (P-AXIS-00063)
P-AXIS-00063 | Time slot calculation (SERCOS) | |
Description | This value defines whether a time slot calculation is executed or the values defined in the axis machine data list are used directly. | |
Parameter | antr.sercos.eval_calc_slot | |
Data type | UNS16 | |
Data range | 0: Parameter are calculated 1: Parameter in machine data list are used 2: Currently not used | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 0 | |
Drive types | SERCOS | |
Remarks | The validity of the parameter P-AXIS-00063 depends on the setting of the parameter P-STUP-00005 . This parameter is not available under TwinCAT. |