Time slot calculation (P-AXIS-00063)

P-AXIS-00063

Time slot calculation (SERCOS)

Description

This value defines whether a time slot calculation is executed or the values defined in the axis machine data list are used directly.

Parameter

antr.sercos.eval_calc_slot

Data type

UNS16

Data range

0: Parameter are calculated

1: Parameter in machine data list are used

2: Currently not used

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

SERCOS

Remarks

The validity of the parameter P-AXIS-00063 depends on the setting of the parameter P-STUP-00005 . This parameter is not available under TwinCAT.