Velocity scaling factor (P-AXIS-00379)

P-AXIS-00379

Velocity scaling factor (PROFIDRIVE)

Description

Thiss parameter supplies the velocity scaling factor set in the drive to the CNC.

This value can be read with a drive set-up tool from the drive and has to be entered in this parameter.

For SIMODRIVE 611 drives it is the parameter P880, for SINAMICS drives it is parameter P2000.

Parameter

antr.profibus.drive_velocity_base_value

Data type

UNS32

Data range

1 … MAX(UNS32)

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

16384

Drive types

Profidrive

Remarks