Velocity scaling factor (P-AXIS-00379)
P-AXIS-00379 | Velocity scaling factor (PROFIDRIVE) | |
Description | Thiss parameter supplies the velocity scaling factor set in the drive to the CNC. This value can be read with a drive set-up tool from the drive and has to be entered in this parameter. For SIMODRIVE 611 drives it is the parameter P880, for SINAMICS drives it is parameter P2000. | |
Parameter | antr.profibus.drive_velocity_base_value | |
Data type | UNS32 | |
Data range | 1 … MAX(UNS32) | |
Axis types | T, R, S | |
Dimension | T: ---- | R,S: ---- |
Default value | 16384 | |
Drive types | Profidrive | |
Remarks |
|