Relative negative offset limit (P-AXIS-00137)

P-AXIS-00137

Relative negative offset limit in manual mode

Description

The parameter defines the relative negative offset limit.

Parameter

handbetrieb.offsetgrenze_neg

Data type

SGN32

Data range

MIN(SGN32) ≤ offsetgrenze_neg ≤ 0

Axis types

T, R

Dimension

T: 0.1µm

R: 0.0001 °

Default value

-1000000

drive types.

----

Remarks

If both parameters offsetgrenze_neg and offsetgrenze_pos are set to 0, offset monitoring is inactive!