Filter - frequency (P-AXIS-00067)

P-AXIS-00067

Characteristic frequency of the axis-specific command value filter

Description

- The frequency range parameter defines the following standard filters:

  • Low-pass: Beginning of cut-off frequency range (ideal filter)
  • High-pass : Beginning of pass-band frequency range (ideal filter)
  • Band-pass and band-stop filters : Middle frequency

- This parameter defines the first natural frequency to be suppressed for the HSC NoVib

Parameter

filter[i].fg_f0

Data type

REAL64

Data range

0 ≤ fg_f0 < 0.5/Tfall   (where Tfall is the NC cycle time)

Axis types

T, R, S

Dimension

T: Hz

R,S: Hz

Default value

3.000000e+001

Drive types

----

Remarks