Order of the actual speed value filter of the master axis(P-AXIS-00623)

P-AXIS-00623

Order of the actual speed value filter of the master axis (throughfeed machining)

Description

The order (number of filtered values) of the actual speed value filter of the master axis is defined with this parameter. The filter is off in the case of order 0. An FIR low-pass filter is used automatically.

Parameter

conv_sync.order_v_filter

Data type

UNS32

Data range

0 ≤ order_v_filter ≤ 1000

Axis types

T, R, S

Dimension

T: ----

R, S: ----

Default value

20

Drive types

----

Remarks

Parameter available in TwinCAT as of CNC Build V3.1.3108.2