Name of the list file for axis parameters (P-STUP-00015)
P-STUP-00015 | Name of the list file for axis parameters |
Description | This parameter is used cross-channel to define the names of axis parameter data files. The number of axis parameter data files must correspond to the number of axis parameter data records. If more files are specified than are contained in P-STUP-00014 (zahl_mds), the excess files are not considered. Vice versa, if the system attempts to open unknown files, error messages are output and controller start-up is aborted. |
Parameter | achs_mds[i] where i = 0 ... 31 (maximum number of axes in the system: 32, application-specific) |
Data type | STRING |
Data range | Maximum 256 characters (application-specific) |
Dimension | ---- |
Default value | * |
Remarks | This parameter is used automatically in TwinCAT systems. * Note: The default value of variables is a blank string. |