Number of records to be read in (P-STUP-00100)
P-STUP-00100 | Number of records to be read in |
Description | This parameter specifies an upper limit for the number of parameter data records to be read in. It serves to allocate memory during controller start-up. An error is issued if this number is exceeded while reading in the records. |
Parameter | vol_comp[i].max_records |
Data type | SGN32 |
Data range | 0 … MAX(SGN32) |
Dimension | ---- |
Default value | 0 |
Remarks |
|