Waiting cycles before evaluation of PLC activation (P-STUP-00172)
P-STUP-00172 | Waiting cycles before evaluation of PLC activation |
Description | Waiting cycles in CNC ticks after an error has occurred before the PLC's activation mask for the filter rules is evaluated. |
Parameter | error_plc_wait_cycles |
Data type | UNS32 |
Data range | 0 ... MAX(UNS32) |
Dimension | ---- |
Default value | - |
Remarks |
|