Error action (P-STUP-00187)
P-STUP-00187 | Error action |
Description | Action that is to be performed if an error occurs. |
Parameter | error_filter[i].action where i = 0 ... 3 (maximum number of filters, application-specific) |
Data type | STRING |
Data range | ACTION = NONE | DRIVE_STATE_REQ | PRE_RUN_STATE_REQ | RUN_STATE_REQ
NONE: No action DRIVE_STATE_REQ: Read out drive status PRE_RUN_STATE_REQ: Error at start-up of the controller bus in PRE-run state RUN_STATE_REQ: Error at start-up of the controller bus in Run state |
Dimension | ---- |
Default value | * |
Remarks | For SERCOS drive profiles: DRIVE_STATE_REQ: S-0-0095 diagnostic PRE_RUN_STATE_REQ: S-0-0021: list of unknown operation data in CP2 -> CP3, command 127 RUN_STATE_REQ: S-0-0022: list of unknown operation data in CP3 -> CP4, command 128 For ProfiDrive profiles: <all actions> Parameter 945
For CANopen profiles <all actions> Parameter ID603F * Note: The default value of variables is a blank string. |