Including ball radius in PCS measurement value (P-CHAN-00311)

P-CHAN-00311

Include ball radius in calculation of PCS measured value

Description

This parameter controls the inclusion of the touch probe ball radius in the PCS measured value (V.A.MEAS.PCS.VALUE.<Axis>), see also the chapter on Programming in [FCT-C4]).

Parameter

meas_pcs_value_no_probe_radius

Data type

BOOLEAN

Data range

0: The ball radius of the probe is included in the PCS measured value (default). *

1: The ball radius of the touch probe is not included in the PCS measured value.

Dimension

----

Default value

0

Remarks

* The ball radius can only be considered if the probe is defined as a separate tool and is selected by the T/D word before the measurement travel. Additionally the ball radius must be entered as 'tool radius' in the tool data record.