Including ball radius in PCS measurement value (P-CHAN-00311)
P-CHAN-00311 | Include ball radius in calculation of PCS measured value |
Description | This parameter controls the inclusion of the touch probe ball radius in the PCS measured value (V.A.MEAS.PCS.VALUE.<Axis>), see also the chapter on Programming in [FCT-C4]). |
Parameter | meas_pcs_value_no_probe_radius |
Data type | BOOLEAN |
Data range | 0: The ball radius of the probe is included in the PCS measured value (default). * 1: The ball radius of the touch probe is not included in the PCS measured value. |
Dimension | ---- |
Default value | 0 |
Remarks | * The ball radius can only be considered if the probe is defined as a separate tool and is selected by the T/D word before the measurement travel. Additionally the ball radius must be entered as 'tool radius' in the tool data record. |