Influence of time override on dwell time (P-CHAN-00111)

P-CHAN-00111

Influence of time override on dwell time

Description

This parameter defines whether the dwell time function is influenced by the time override real-time function.

Parameter

time_override_weight_dwell_time

Data type

BOOLEAN

Data range

0: A change of override has no influence on dwell time.

1: The duration of a programmed dwell time changes in relation to the time override specified by the PLC. For example, this means that at 50% time override, the programmed dwell time of 1s is increased by a factor of 2 to 2s

Dimension

----

Default value

0

Remarks