Enabling gear changes of the main spindle (P-CHAN-00052)

P-CHAN-00052

Enable mechanical gear change of main spindle

Description

This parameter enables or disables gear changes for the main spindle.

Parameter

main_spindle_gear_change

Data type

BOOLEAN

Data range

0: Spindle gear changes disabled for the main spindle

1: Spindle gear changes enabled for the main spindle

Dimension

----

Default value

0

Remarks

The M functions to select the gear speeds of the main spindle M40–45 are activated by the parameter P-CHAN-00052 in the channel parameter list. The M functions M40–45 can be freely used if gear changes are disabled.