Time-based block ahead limiting (P-CHAN-00269)
P-CHAN-00269 | Selecting time-based decoder block ahead limiting |
Description | This parameter activates and configures the time-based limiting of the decoder ahead function by setting a value unequal to zero. The value defines the maximum time in microseconds by which the decoder may be ahead of the interpolator. |
Parameter | max_time_ahead |
Data type | REAL64 |
Data range | 0: No decoder block ahead limiting (default). >0: The time-based decoder block ahead limiting function is active after program start at once and remains selected until main program end M30. |
Dimension | µs |
Default value | 0 |
Remarks | Only one type of decoder block ahead limiting function may be active. This is active immediately after program start and it remains selected until main program end M02/M30. |