Exact stop with rapid traverse (P-CHAN-00235)

P-CHAN-00235

Exact stop after every rapid traverse

Description

If this parameter is set to 1, an exact stop (G60) is implicitly executed after every rapid traverse block (G00). Active smoothing (G61, G261) is then suppressed for this NC block

Parameter

exact_stop_after_g00

Data type

BOOLEAN

Data range

0: Rapid traversing movement without exact stop (G60) (default).

1: Rapid traverse motion followed by automatic exact stop (G60).

Dimension

----

Default value

0

Remarks