Reserved distance for time calculation (P-CHAN-00307)
P-CHAN-00307 | Time preview: Reserved distance for time calculation |
Description | The time preview function allows the calculation of the time that the CNC needs to travel a certain distance, taking into consideration the current speed profile. This parameter specifies the distance. The calculated time is output on the PLC interface The specified distance refers to the tool centre point path in the default setting but can be switched to the workpiece contour by P-CHAN-00340 . The parameter value 0 deactivates the time preview. |
Parameter | position_lookahead_distance |
Data type | UNS32 |
Data range | 0 ... MAX(UNS32) |
Dimension | 0.1µm |
Default value | 0 |
Remarks |
|