Select specific manufacturer-specific procedures for drive controllers (P-AXIS-00535)

P-AXIS-00535

Select specific manufacturer-specific procedures for drive controllers

Description

Many drive controllers do not always conform completely to the interface specifications. In conjunction with P-AXIS-00536 this parameter can activate manufacturer- and device-specific special procedures to still operate the drive controller in the CNC.

Parameter

kenngr.vendor_id

Data type

UNS32

Data range

 0: No special procedures active

100: Specify the activated special procedures in P-AXIS-00536 in the form of a bit string.

The purpose of values 1 to 9 are to enable a manufacturer-specific set of special procedures and they only exist for the purpose of downward compatibility.

Axis types

T, R, S

Dimension

T: ----

R,S: ----

Default value

0

Drive types

----

Remarks