Error message content, body machine data

Machine data

Description

Error information in relation to an update of machine data

Data type

HLI_RUMPF_MDS

ST path

pMachineDataErr : POINTER TO HLI_RUMPF_MDS;

pMachineDataErr := ADR(gpCh[channel_idx]^.mc_error.satz_r.rumpf.maske.err_mask[0]);

 

Description

Significance of list

ST path

.listen_typ

Data type

UINT

Value range

Value

Meaning

1

Manual mode list

2

Channel parameter list

3

Axis parameter list

4

Zero offset list

5

Tool parameter list

6

Position offset list

7

Start-up list

9

Axis compensation list

12

List of external variables

 

 

Description

Name of wrong structure

ST path

.strukt_name.zeichen

Data type