Behaviour of the slave axis at the modulo limit
The behaviour of the slave at the modulo limit must be specially defined.
By default, the slave will always move within its modulo limits, i.e. it maximally undergoes one revolution in the same direction.
If an endlessly rotating slave is required, either "EndlessPositive" or "EndlessNegative" must be specified in the start mode of the FB MC_CamIn. The slave will then endlessly rotate beyond the modulo limit in the positive or negative direction of rotation.
Cases for all three variants with regard to the behaviour of the slave axis at the modulo limit are shown in Figures 2, 3 and 4.
Example
The following camming table was used in all three examples:
Tablename = Smallest_Table # Table name
Table-ID = 404 # Table-ID
Tabletype = 7 # Table type, 7= 2-column, SGN32 format
Functiontype = 4 # Interpol. type, 4= LINE-POLY5, 5= POLY5-LINE
Lines = 2 # Number of lines
Begintable # Beginning of table
100000 0
1500000 3400000
EndTable